The NFire Solution
How NFire's Wireless Architecture Makes Hospital Retrofit Possible Without Pausing Operations
NFire is India’s first wireless addressable AIoT fire alarm system, developed by Atigo Enterprises Limited at IIT Gandhinagar Research Park and compliant with IS/ISO 7240 and EN54. Its architecture is purpose-built for environments where cabling is either impossible or clinically unacceptable — which describes the overwhelming majority of Indian hospital retrofit scenarios.
Direct Sensor-to-SCM Connectivity
NFire does not operate as a mesh network. Each sensor — smoke, heat, gas, carbon monoxide, or multi-criteria — communicates directly with its assigned Sensor Control Module (SCM). This direct connectivity model ensures that no sensor’s communication path depends on the operational status of any other sensor, eliminating single points of failure that are inherent in mesh topologies. The SCM requires only a single power connection, not a conduit run or data cable. In a hospital setting, this means a complete floor can be instrumented over a single working day, with no ceiling penetrations and no structural modifications.
Zone-by-Zone Commissioning
Because NFire sensors are wireless, they can be commissioned one zone at a time and added to the live system without interrupting coverage in adjacent zones. A hospital retrofit can therefore proceed floor by floor, wing by wing, and in some cases room by room — with the existing system (however limited) continuing to provide coverage in areas not yet upgraded. There is no period during which the hospital operates with a partial system and full gaps.
NFire Panels and Ecosystem
NFire’s panel range — the N7, N70, N700, and N707 — scales from single-floor clinics to multi-building hospital campuses. The NFire Command Centre provides multi-user, real-time graphical floor plan monitoring, giving hospital fire safety officers a live view of every sensor’s status across every wing simultaneously. The NFire Connect mobile application enables remote access and incident coordination, meaning the hospital safety team can receive and respond to alerts without being physically present at the panel.
Retrofit Journey: What the Process Looks Like
Site Assessment and Zone Mapping
NFire engineers conduct a wireless signal survey across the hospital to confirm coverage geometry. High-risk zones ICU, OT, CSSD, oxygen manifold rooms, neonatal units, and medication stores are mapped first, establishing the sequencing priority for commissioning.
Panel Installation and System Initialisation
The NFire panel is installed in the fire command centre location, along with the SCM units for each zone. No cable runs are required — SCMs connect to a single power supply only. The system is initialised and linked to the NFire Command Centre cloud platform.
Phased Sensor Commissioning Zone by Zone
Sensors are installed and commissioned one zone at a time, beginning with highest-risk clinical areas. Each zone goes live before moving to the next — the hospital is never in a state where multiple zones are simultaneously offline or only partially covered.
System Acceptance Testing and Fire NOC Documentation
Full system testing is conducted per IS/ISO 7240 protocols, generating the documentation required for Fire NOC submission. NFire’s compliance with IS/ISO 7240, EN54, and NBCS 2026 requirements is documented and ready for fire authority review.
Handover to Hospital Safety Team
Hospital safety officers and maintenance teams are trained on the NFire Command Centre and NFire Connect app. 24/7 cloud monitoring is activated, with the NFire emergency response platform providing continuous coverage alongside the hospital’s internal protocols.